FRP pipe is consist of inner layer, Structural layer and outer layer. Its characteristics are:
Diameter (mm) | DN50, DN80, DN100, DN150, DN200, DN250, DN300, DN350, DN400, DN450, DN500, DN600, DN700, DN800, DN900, DN1000, DN1100, DN1200, DN1300, DN1400, DN1500, DN1600, DN1800, DN2000, DN2400, DN2500, DN2600, DN2800, DN3000, DN3200, DN3400, DN3500, DN3600, DN3800, DN4000 |
Pressure (MPa) | gravity, PN0.25, PN0.6, PN1.0, PN1.2, PN1.6, PN2.0, PN2.5, PN3.2 |
Stiffness (N/m2) | SN2500, SN5000, SN7500, SN10000, SN15000, SN20000, SN30000, SN50000 |
seaworthy packaging & shipping, telescope packaging
6.1 The section of the ditch
6.1.1 The surface of the ditch should be connected smoothly, and the wall of the ditch should be vertical.
6.1.2 The width of the ditch above the pipe only needs enough space to ram the backfill of the two sides of the pipe. If it is necessary can dig a hole in the coupling position, it means the width of the ditch need enlarge 2 meters, the length need enlarge 2 meters, the bottom of the ditch need decrease 1.5 meters, this hole should be filled up and rammed after backfill.
6.1.3 The depth of the ditch can be defined according to the following factors, such as the pre-designed device in pipeline, property, dimension of the pipe, the property of the soil, the static load and the dynamic load.
Fig.7
A---The backfill on site
B---The backfill
C---Steady support
D---3 times of the diameter
E---The backfill in the pipe area the minimum height is 70 percent of the diameter
F---Base bed minimum15cm
G---Base minimum 15cm
our company established by several-manufacturers jointly, firstly product quality is ensured, secondly is delivery time is guranranteed.
We will provide the complete service for the bidding goods prior to sale and post-sale, such as fabrication, transportation, spare parts and accessories. The technical staffs will install and debug at jobsite, make the equipment reach the requirements of the property and settle any problems arisen from design or fabrication during the installation freely.